成人午夜高潮视频,亚洲欧美色图小说,性爱视频在线播放,精品久久蜜桃

Small meteorological station
Small meteorological station

Product Center

Contact Us

Shandong Wanxiang Environmental Technology Co., Ltd

contacts :Manager MAO

Telephone :15666889815

QQ:1950883583

Company Address:The second floor of the first accelerator of the Optoelectronic Industry Park, No. 155 Incubation Second Lane, High tech Zone, Weifang City, Shandong Province

Ammonia nitrogen detector

Ammonia nitrogen detector

update time :2025-12-19

Model:WX-SS5

Product Price: Electronic Negotiation

Product brand: Wanxiang Environment

Ammonia nitrogen detector, also known as portable multi parameter water quality analyzer, is an instrument used to detect ammonia nitrogen and pH parameters in water quality. The instrument is easy to operate, stable in performance, accurate in measurement, and has a wide detection range, making it convenient for users to conduct water quality testing in the field or laboratory at any time.
product details
  1. Ammonia nitrogen detector Product Introduction

Ammonia nitrogen detector, also known as portable multi parameter water quality analyzer, is an instrument used to detect ammonia nitrogen and pH parameters in water quality. The instrument is easy to operate, stable in performance, accurate in measurement, and has a wide detection range, making it convenient for users to conduct water quality testing in the field or laboratory at any time.

The SS5 model portable multi-parameter water quality measuring instrument is an electrode method water quality analysis instrument that uses full digital electrode detection to detect ammonia nitrogen and PH parameters of water quality. The instrument is equipped with a self-developed FTIOT operating system, which has simple operation, stable performance, accurate measurement, wide detection range, and has a built-in high-capacity rechargeable lithium battery, which is convenient for users to conduct water quality inspection at any time in the field and in the laboratory.

2.Ammonia nitrogen detector  Host parameters

Charging input voltage4.5V-5.5V
Charging current<2A
Screen size3.5 inches
Screen resolution480*800 ☆
Screen interfaceMIPI DSI ☆
USB port2 (Support external expansion of mouse, keyboard, 4G, etc.) ☆
Type-C1 (Support external expansion of mouse, keyboard, 4G, etc.) ☆
RS4852 (Support Modbus, json, asc input, etc.)
External sensor power supply voltage12V
External sensor power supply current1A
operating systemftiot (based on Linux-5.4) ☆
CPU2*Cotex-A7, 650Mhz ☆
RAM512M DDR3 ☆
Flash8G-64G
OpenGLES 2.0 ☆
Wifisupport
4GSelection
buttonsupport
Capacitive touch screensupport
Software ArchitectureB/S ☆
Web accessSupport ☆
MTP modeSupport ☆
Multi-terminal loginSupport ☆
IPV6Support ☆
Sensor communication methodRS485, TCP, UDP, Http ☆
Data forwarding methodRS485, TCP, UDP, Http ☆
Remote SSHSupport ☆
Remote debuggingSupport ☆

3. Sensor parameters and configuration

Serial numbernameMeasurement rangeprincipleMeasurement accuracyResolutionConfigurationRemark
1temperature0~50℃High-precision digital sensor±0.3℃0.01℃

2pH0~14 (ph)Electrochemistry (salt bridge)± 0.1PH0.01

3ORP-1500mv~1500mvElectrochemistry (salt bridge)± 6mv1mV

4Conductivity0~5000uS/cm, 0~10000uS/cmContact electrode method± 1.5%1uS/cm

5TDS0-10000ppm 0-200pptContact electrode method±1.5%; ±0.1°C1ppm 0.01ppt

6salinity0-10000ppm 0-200pptContact electrode method±1.5%; ±0.1°C1ppm 0.01ppt

7Sludge concentration0~20.000g/LScattering light method±5% (depending on sludge homogeneity)0.001g/L

8Turbidity0~40NTU (low turbidity)Scattering light method± 1%0.1NTU
Optional
0~1000NTU (medium turbidity)Scattering light method± 1%
0~3000NTU (high turbidity)Scattering light method± 1%
9Dissolved oxygen0~20mg/LFluorescence life method± 2%0.01mg/L

10Ammonia nitrogen0~100mg/l, 0~1000.00mg/lIon Selection Electrode Method±1mg0.01mg?Range optional
11Suspension0~2000mg/LScattering light method±5% (depending on sludge homogeneity)0.1mg/L

12Residual chlorine0~5.00 mg/LIon Selection Electrode Method±5% of reading0.01mg/L
The best accuracy is when the flow rate is 0.42m/s-0.85m/s
13Chloride ions0-3500.0mg/LIon Selection Electrode Method±5%0.1mg/L

14Total hardness0~1000.0mg/LIon Selection Electrode Method±10% of reading0.1mg/L

15cod0~500mg/ LUV254 absorption method±5%0.1mg/L
COD and chlorophyll have automatic cleaners, which can prevent biological adhesion and avoid light window contamination, so as to ensure that long-term monitoring is still stable; automatic cleaning time and cleaning times can be set, and the power consumption is 0.7W
16Chlorophyll0~400ug/LFluorescence methodR2>0.9990.01ug/L



Product address:http://m.0757gl.com/en/shuizhi/1408.html
Hello, my friend!
What kind of support do you need? Our products is sure to satisfy you.
*Name
*Email
WeChat
Phone
Country
*Message
主站蜘蛛池模板: 沂源县| 香格里拉县| 修文县| 卓尼县| 瑞昌市| 济宁市| 太保市| 昌江| 冷水江市| 甘洛县| 绩溪县| 都匀市| 桑植县| 昌邑市| 普宁市| 阳春市| 岳阳县| 鹤壁市| 三亚市| 丰都县| 娱乐| 太仆寺旗| 邹平县| 读书| 松溪县| 五指山市| 苏尼特左旗| 荥阳市| 潞城市| 楚雄市| 桃源县| 丰镇市| 浪卡子县| 沂水县| 泾川县| 南雄市| 天祝| 茂名市| 扬中市| 五原县| 苍南县|